I
ndividuals will perform a HAZOP on a single unit operation of a model power plant based off of the
National energy Technology Laboratory (NETL) Vol 1 of ‘Cost and Performance Baseline for Fossil Energy
Plants’.You can
download the file from this link:
https://www.netl.doe.gov/projects/files/CostAndPer…
ilEnergyPlantsVol1BitumC
oalAndNGtoElectBBRRev4-1_092
419.pdf
Each
student
will choose
a specific unit of the plant
from study area 1
–
7
(identified in red box and
labeled as Main Unit
).
Table shows
the study area
and the corresponding pages of the document
that
are related to that unit. Perform a HAZOP of the unit, detailing possible deviations in normal operation
and what would be the predicted outcomes of the deviations.
Present this information as a table
.
Identify if the deviations cause issues with prod
uct quality (such as reduced energy production) or a
hazard (such as loss of containment of steam).
You do not need to detail every possible deviation,
but
should
include enough details to address
at least
4 deviation of each major inlet/outlet
node
. You s
hould be able to identify
at least
2
nodes
(CHE
5292 students, please select 3 nodes
). Summarize the findings
of your HAZOP analysis and note which deviations you were not able to find corrective actions for
(1
-2 pages)
. Suggest a method used for investigating corrective actions.
Here is the conte
nt of the report: Cover page, abstract,
introduction about the unit operation, HAZOP
table, discussions and recommendations, and references (IEEE style). Please use Times New Roman,
single space, 12 Font, 1 in margin.
HAZOP Assignment for ChE 4284/5292
Individuals will perform a HAZOP on a single unit operation of a model power plant based off of the
National energy Technology Laboratory (NETL) Vol 1 of ‘Cost and Performance Baseline for Fossil Energy
Plants’. You can download the file from this link:
https://www.netl.doe.gov/projects/files/CostAndPerformanceBaselineForFossilEnergyPlantsVol1BitumC
oalAndNGtoElectBBRRev4-1_092419.pdf
Each student will choose a specific unit of the plant from study area 1 – 7 (identified in red box and
labeled as Main Unit). Table shows the study area and the corresponding pages of the document that
are related to that unit. Perform a HAZOP of the unit, detailing possible deviations in normal operation
and what would be the predicted outcomes of the deviations. Present this information as a table.
Identify if the deviations cause issues with product quality (such as reduced energy production) or a
hazard (such as loss of containment of steam). You do not need to detail every possible deviation, but
should include enough details to address at least 4 deviation of each major inlet/outlet node. You should
be able to identify at least 2 nodes (CHE 5292 students, please select 3 nodes). Summarize the findings
of your HAZOP analysis and note which deviations you were not able to find corrective actions for (1-2
pages). Suggest a method used for investigating corrective actions.
Here is the content of the report: Cover page, abstract, introduction about the unit operation, HAZOP
table, discussions and recommendations, and references (IEEE style). Please use Times New Roman,
single space, 12 Font, 1 in margin.
If you do not understand the assigned units please contact the instructor. You do not have to read the
entire NETL report.
Study area
1
2
3
4
5
6
7
Unit
Carbon Dioxide Recovery unit; Pre-scrubber and
Absorber
Carbon Dioxide Recovery unit; Stripper and Amine
solvent regeneration
Sour water stripper
Flu gas desulphurization unit (absorber tower only)
Activated carbon injection unit
Pulverized Coal Boiler
High Pressure/Intermediate Pressure Turbine
Pages
356-359
356-359
81-84
351-352
347-350
404
405
Grading;
Identification of 2 (or 3) nodes; 20 points
Use of guide words, causes, and consequences to analyze deviations; 60 points
Summary of HAZOP with recommendations for follow up analysis to investigate deviations that could
not be properly addressed; 20 points
1
Study Area 1; Carbon Dioxide Recovery unit; Pre-scrubber and Absorber from page 357 of assigned NETL
report
Main Unit
2
Study area 2; Carbon Dioxide Recovery unit; Stripper and Amine solvent regeneration from page 357 of
assigned NETL report
Main Unit
3
Study Area 3; Sour Water Stripper from page 83 of assigned NETL report
Main Unit
4
Study Area 4; Flu gas desulphurization unit from page 351 of assigned NETL report
Main Unit
5
Study Area 5; Activated Carbon injection unit from page 349 of assigned NETL report
Main Unit
6
Study Area 6; Pulverized Coal Boiler from page 404 of assigned NETL report
Main Unit
7
Study Area 7; High Pressure/Intermediate Pressure Turbine from page 405 of assigned NETL report
Main Unit
8
Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.
You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.
Read moreEach paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.
Read moreThanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.
Read moreYour email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.
Read moreBy sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.
Read more